Collected Item: “Analysis of the correlation between modified secondary and primary compression index on the example of old municipal waste in Serbia ”
Врста публикације
Рад у зборнику
Верзија документа
објављена
Језик
енглески
Аутор/и (Милан Марковић, Никола Николић)
Dragoslav Rakić, Irena Basarić Ikodinović, Jovana Janković, Tina Djurić
Наслов рада (Наслов - поднаслов)
Analysis of the correlation between modified secondary and primary compression index on the example of old municipal waste in Serbia
Назив конференције (зборника), место и датум одржавања
20th International Conference on Soil Mechanics and Geotechnical Engineering (ICSMGE)
Издавач (Београд : Просвета)
ICMS Australasia
Година издавања
2022
Сажетак рада на енглеском језику
The paper presents the results related to the determination of the index of primary and maximum and minimum indices
of secondary compression, i.e. modified primary and secondary compression indices (Cc, Cc', C'min, C'max), obtained by laboratory
testing of artificially prepared municipal waste samples (three series of 9 samples in total) in an oedometer apparatus with a diameter
of 20 cm. Old municipal waste was used, which was taken from two landfills in Serbia, one that is no longer in use (Ada Huja in
Belgrade) and the other that is still in use (city landfill in Novi Sad). The duration of the test of the first series was 74 days, the second
series 161 days and the third series 147 days. From the results it was possible to present the relationship of these indices and the initial
void ratio as well as the influence of normal stresses on the ratio of modified secondary and primary compression indices (C'max/Cc'
and C'min/Cc'). The established relation can be useful for obtaining the secondary compression index for a significantly shorter
duration of the experiment, since a time of 15 min has been adopted for the completion of the primary compression.
of secondary compression, i.e. modified primary and secondary compression indices (Cc, Cc', C'min, C'max), obtained by laboratory
testing of artificially prepared municipal waste samples (three series of 9 samples in total) in an oedometer apparatus with a diameter
of 20 cm. Old municipal waste was used, which was taken from two landfills in Serbia, one that is no longer in use (Ada Huja in
Belgrade) and the other that is still in use (city landfill in Novi Sad). The duration of the test of the first series was 74 days, the second
series 161 days and the third series 147 days. From the results it was possible to present the relationship of these indices and the initial
void ratio as well as the influence of normal stresses on the ratio of modified secondary and primary compression indices (C'max/Cc'
and C'min/Cc'). The established relation can be useful for obtaining the secondary compression index for a significantly shorter
duration of the experiment, since a time of 15 min has been adopted for the completion of the primary compression.
Укупан број страна (само уколико стране нису нумерисане)
6
Кључне речи на енглеском (одвојене знаком ", ")
municipal solid waste; secondary compression index; ratio of modified secondary and primary compression index.
Линк
https://icsmge2022.org/contact.php